CT FIRE-1 Fire Rated Duct

    

CT Fire-1 fire rated ductwork coated with 0.05 mm Fire-1 paint can provide up to 120 minutes fire protection in accordance with BS 476 Part24 standard.

Quality Assurance

  • BS476 Part24 / ISO 6944 fireproof duct test
  • Warringtonfire certificate (CF5522)
  • National fire agency certificate (1080822417)
  • CPA certificate for wall penetration seal
  • Design as per DW144 standard

Full Range Certified

  • CT FIRE-1 fire rated ducts
  • FIRE-1 fireproof paint
  • FS703 fireproof sealant  
  • Superwool fireproof gasket

Application

  • Wall Penetration seal for fire compartment
  • Smoke extract/outlet ventilation
  • Ventilation system, car park extraction, pressurization

Advantage

Assurance

Customer Benefits

Fireproof ductwork

 international certificates

safe & security

    Fire proof - 2 hours

thinner film (0.05 mm)

wider application area

   Super fast drying

Surface dry 1 hour

more convenience

   Reliable quality

weather resistance

more cost-effective

   Full range certified products 

most reasonable price

flexible application

CT FIRE-1 Fireproof Ductwork

Fire characteristics

  • Building structure is not strong: When the temperature reaches to 600°C, the steel will lose its strength about 50%. Non-fire rated ducts can be responsible for the spread of fire because of deformation and collapse under the impact of the fire.

  • The fire grows rapidly

  • There are no fire compartments or be damaged

  • More than 60% of the death rate is due to smoke inhalation..

Fire resistant ductwork

  • Prevent flame entering or leaving the ductwork;
  • Limit the spread of flame;
  • Maintain the integrity of the fire compartment

Fire Department Regulations and Construction Code:All fire resistant ductwork shall be tested to BS476 part24:1987.

Chan Tzu CT Fire-1 Fireproof ductwork complies with BS476 Part24/ISO 1944  for 120 minutes of Stability and Integrity. 

BS 476 Part 24 Standard: 

  • Duct A (Fire Outside) – 120 min.
  • Duct B (Fire Inside)- 120 min.
  • Smoke Outlet Duct (Fire Outside/Inside)-120 min.

BS476 Part24測試標準

  • Stability: Stability failure shall be deemed to have occurred in duct A within the furnace and in ducts A and B outside the furnace while the duct collapses.
  • Integrity: The formation on the unexposed side of holes, cracks or openings that allow flames or hot gases to escape.
  • Smoke Outlet Duct: shall retain at least 75% of its cross sectional area to be functional

 

 

 

Headquarter

No.77, Ln. 71, Zhongzhuang St., Jiuru Township, Pingtung County 90442, Taiwan
Tel: 886-8-739 0858 Fax: 886-8-739 0838
Email: chan.tzu.tw@gmail.com

Certification

ISO 9001:2015 Certificate
Warringtonfire FR Duct Test Report
Warringtonfire FR Duct Certificate
CNS15814 Penetration Sealing Certificate
CNS15816 FD Certificate
PF Insulation Duct Certificate


About certificate Laboratory Product
Industrial Fans Damper Series gate louver equipment Smoke Control and Fire Resistant Ductwork
Performance Quotation Contact